Product Name:
Goat Alpha-amylase (α-AMS) ELISA Kit
Cat.#:
JL54913
Regulatory Status:
Alternative:
amylase; Alpha-amylase 1;1;4-alpha-D-glucan glucanohydrolase 1;Salivary and hepatic alpha-amylase;Amy1;Amy-1-a;Amy1a
Detection Method:
ELISA
Assay Type:
Competitive
Detection Range:
1.56-100ng/mL
Sensitivity:
0.81ng/mL
Specificity:
This kit recognizes Goat α-AMS in samples. No significant cross-reactivity or interference between Goat α-AMS and analogues was observed.
Sample Type:
Serum;plasma and other biological fluids
Assay Procedure:
Research Area:
Neuroscience
Product Datasheets
| α-AMS
The α-amylases(CAS 9014–71–5) (alternative names: 1,4-α-D-glucan glucanohydrolase; glycogenase) are calcium metalloenzymes. By acting at random locations along the starch chain, α-amylase breaks down long-chain saccharides, ultimately yielding either maltotriose and maltose from amylose, or maltose, glucose and "limit dextrin" from amylopectin. They belong to glycoside hydrolase family 13.Because it can act anywhere on the substrate, α-amylase tends to be faster-acting than β-amylase. In animals, it is a major digestive enzyme, and its optimum pH is 6.7–7.0.In human physiology, both the salivary and pancreatic amylases are α-amylases.The α-amylase form is also found in plants, fungi (ascomycetes and basidiomycetes) and bacteria (Bacillus).| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (ng/mL) | 100 | 50 | 25 | 12.5 | 6.25 | 3.12 | 1.56 | 0 |
| OD | 0.15 | 0.2 | 0.31 | 0.52 | 0.83 | 1.29 | 1.63 | 2.34 |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Goat α-AMS spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Serum(n=8) | 84-101 | 96 |
| Plasma(n=8) | 92-105 | 100 |
| Linearity
Samples were spiked with high concentrations of Goat α-AMS and diluted with Universal Diluent to produce samples with values within the range of the assay.| Serum(n=4) | Plasma(n=4) | ||
| 1 : 2 | Range (%) | 82-93 | 88-96 |
| Average (%) | 90 | 93 | |
| 1 : 4 | Range (%) | 89-103 | 87-110 |
| Average (%) | 93 | 98 |
Size
Quantity
Price ($)
48T
1
520 / 520
96T
1
640 / 640


