Product Name:
Digoxin (DGX) ELISA Kit
Cat.#:
JL54808
Regulatory Status:
Alternative:
Cardigox; Cardiogoxin; Cardioxin; Cardoxin; Coragoxine; Digacin; Digicor; Digomal; Digon; Digosin; Digoxigenin; Digoxine Navtivelle; Digoxina-Sandoz; Digoxin-Sandoz; Digoxin-Zori; Dilanacin
Detection Method:
ELISA
Assay Type:
Competitive
Detection Range:
3.12-200ng/mL
Sensitivity:
1.47ng/mL
Specificity:
This kit recognizes DGX in samples. No significant cross-reactivity or interference between DGX and analogues was observed.
Sample Type:
Serum, plasma, tissue homogenate, cell lysate, cell culture supernatant and other biological fluids
Assay Procedure:
Research Area:
Pesticide Residues & Drug Metabolism
Product Datasheets
| DGX
Digoxin (commonly known as digitalis) is a medication used to treat various cardiac conditions, most frequently atrial fibrillation, atrial flutter, and heart failure. As one of the oldest drugs in cardiology, it functions by enhancing myocardial contractility, increasing stroke volume and blood pressure, reducing heart rate, and to some extent, prolonging the contraction time range. Digoxin is administered either orally or intravenously, with an elimination half-life of approximately 36 hours under standard dosing in patients with normal renal function.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (ng/mL) | 200 | 100 | 50 | 25 | 12.5 | 6.25 | 3.12 | 0 |
| OD | 0.21 | 0.39 | 0.71 | 1.08 | 1.42 | 1.75 | 1.84 | 2.03 |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of DGX spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Serum(n=8) | 88-102 | 98 |
| Plasma(n=8) | 94-108 | 104 |
| Cell Culture Supernates(n=8) | 96-111 | 106 |
| Linearity
Samples were spiked with high concentrations of DGX and diluted with Universal Diluent to produce samples with values within the range of the assay.| Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
| 1 : 2 | Range (%) | 82-98 | 88-97 | 90-111 |
| Average (%) | 91 | 91 | 97 | |
| 1 : 4 | Range (%) | 89-104 | 87-112 | 105-115 |
| Average (%) | 93 | 98 | 109 |
Size
Quantity
Price ($)
48T
1
320 / 320
96T
1
516 / 516