Ochratoxin A (OTA) ELISA Kit

Home  >  Competitive ELISA Kits  >  Ochratoxin A (OTA) ELISA Kit
Product Name:

Ochratoxin A (OTA) ELISA Kit

Cat.#:

JL18776

Regulatory Status:
Alternative:

Ochratoxin A

Detection Method:
ELISA
Assay Type:
Competitive
Detection Range:
15.6-1000ng/mL
Sensitivity:
7.3ng/mL
Specificity:
This kit recognizes OTA in samples. No significant cross-reactivity or interference between OTA and analogues was observed.
Sample Type:
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Cardiovascular Biology
  • Ochratoxin A (OTA) ELISA Kit
  • Ochratoxin A (OTA) ELISA Kit
  • Ochratoxin A (OTA) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| OTA

Ochratoxin A (OTA), a toxin produced by different Aspergillus and Penicillium species, is one of the most abundant food-contaminating mycotoxins.It is also a common contaminant in water-damaged homes and heating ducts.Humans can be exposed to this toxin through the consumption of contaminated food, especially contaminated grains and pork products, as well as coffee, wine grapes and raisins.The toxin has been found in the tissues and organs of animals, including human blood and breast milk.It, like most toxic substances, has large species and gender-specific toxicological differences.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (ng/mL) 1000 500 250 125 62.5 31.2 15.6 0
OD 0.216 0.298 0.417 0.669 0.955 1.405 1.79 1.865
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Human DAF;CD55 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 81-101 96
Plasma(n=8) 92-105 101
Cell Culture Supernates(n=8) 97-108 105





 

| Linearity

Samples were spiked with high concentrations of Human DAF;CD55 and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4) Cell Culture Supernates(n=4)
1 : 2 Range (%) 83-95 88-96 90-110
Average (%) 91 92 96
1 : 4 Range (%) 89-104 87-108 105-115
Average (%) 93 98 110







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
460 / 460
96T
1
760 / 760