400-0066-400

Melamine (Melamine) ELISA Kit

Home  >  Competitive ELISA Kits  >  Melamine (Melamine) ELISA Kit
Product Name:

Melamine (Melamine) ELISA Kit

Cat.#:

JL48235

Regulatory Status:
Alternative:

Melamine;1,3,5-Triazine-2,4,6-triamine;2,4,6-Triamino-s-triazine;Cyanurotriamide;Cyanurotriamine;Cyanuramide

Detection Method:
ELISA
Assay Type:
Competitive
Detection Range:
0.78-50ng/mL
Sensitivity:
0.34ng/mL
Specificity:
This kit recognizes Melamine in samples. No significant cross-reactivity or interference between Melamine and analogues was observed.
Sample Type:
Serum;plasma;tissue homogenates;cell lysates;cell culture supernates and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Pesticide Residues & Drug Metabolism
  • Melamine (Melamine) ELISA Kit
  • Melamine (Melamine) ELISA Kit
  • Melamine (Melamine) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| Melamine

Melamine is an organic compound with the formula C3H6N6. This white solid is a trimer of cyanamide, with a 1,3,5-triazine skeleton. Like cyanamide, it contains 66% nitrogen by mass, and its derivatives have fire-retardant properties due to its release of nitrogen gas when burned or charred. Ingestion of melamine may lead to reproductive damage, or bladder or kidney stones, and bladder cancer.It is also an irritant when inhaled or in contact with the skin or eyes.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (ng/mL) 50 25 12.5 6.25 3.12 1.56 0.78 0
OD 0.188 0.27 0.389 0.642 0.929 1.38 1.766 1.842
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Melamine spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 81-101 96
Plasma(n=8) 92-105 101
Tissue Homogenates(n=8) 92-105 101





 

| Linearity

Samples were spiked with high concentrations of Melamine and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4) Tissue Homogenates(n=4)
1 : 2 Range (%) 84-95 88-96 90-110
Average (%) 91 93 96
1 : 4 Range (%) 89-103 87-108 105-115
Average (%) 94 98 108







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
620 / 620
96T
1
840 / 840
Top