400-0066-400

Prostaglandin E1 (PGE1) ELISA Kit

Home  >  Competitive ELISA Kits  >  Prostaglandin E1 (PGE1) ELISA Kit
Product Name:

Prostaglandin E1 (PGE1) ELISA Kit

Cat.#:

JL53263

Regulatory Status:
Alternative:

Alprostadil

Detection Method:
ELISA
Assay Type:
Competitive
Detection Range:
15.6-1000pg/mL
Sensitivity:
7.2pg/mL
Specificity:
This kit recognizes PGE1 in samples. No significant cross-reactivity or interference between PGE1 and analogues was observed.
Sample Type:
Serum;plasma and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Immunology
  • Prostaglandin E1 (PGE1) ELISA Kit
  • Prostaglandin E1 (PGE1) ELISA Kit
  • Prostaglandin E1 (PGE1) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| PGE1

Prostaglandin E1 (PGE1) is a naturally occurring prostaglandin with various medical uses. Alprostadil and misoprostol are synthetic forms of prostaglandin E1 used as medications. Lubiprostone, a derivative of prostaglandin E1, is also used as a medication. Prostaglandin E1 is a vasodilator. It has various effects in the body that include opening blood vessels, relaxing smooth muscle, inhibiting clotting, and causing uterine contractions.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (pg/mL) 1000 500 250 125 62.5 31.2 15.6 0
OD 0.14 0.25 0.38 0.72 0.94 1.27 1.54 1.76
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of PGE1 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 84-113 103
Plasma(n=8) 88-115 100





 

| Linearity

Samples were spiked with high concentrations of PGE1 and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4)
1 : 2 Range (%) 90-103 82-108
Average (%) 95 90
1 : 4 Range (%) 94-112 84-106
Average (%) 102 97







 