Product Name:
Vitamin B12 (VB12) ELISA Kit
Cat.#:
JL37366
Regulatory Status:
Alternative:
Vitamin B12;cobalamin
Detection Method:
ELISA
Assay Type:
Competitive
Detection Range:
78-5000pg/mL
Sensitivity:
38.5pg/mL
Specificity:
This kit recognizes VB12 in samples. No significant cross-reactivity or interference between VB12 and analogues was observed.
Sample Type:
Serum;plasma;tissue homogenates;cell lysates;cell culture supernates and other biological fluids
Assay Procedure:
Research Area:
Metabolism
Product Datasheets
| VB12
Vitamin B12, also known as cobalamin, is a water-soluble vitamin involved in metabolism.It is one of eight B vitamins. It is required by animals, which use it as a cofactor in DNA synthesis, and in both fatty acid and amino acid metabolism.It is important in the normal functioning of the nervous system via its role in the synthesis of myelin, and in the circulatory system in the maturation of red blood cells in the bone marrow.Plants do not need cobalamin and carry out the reactions with enzymes that are not dependent on it.Vitamin B12 is a coordination complex of cobalt, which occupies the center of a corrin ligand and is further bound to a benzimidazole ligand and adenosyl group.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (pg/mL) | 5000 | 2500 | 1250 | 625 | 312 | 156 | 78 | 0 |
| OD | 0.216 | 0.298 | 0.417 | 0.669 | 0.955 | 1.405 | 1.79 | 1.865 |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of VB12 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Serum(n=8) | 81-101 | 96 |
| Plasma(n=8) | 93-105 | 101 |
| Cell Culture Supernates(n=8) | 97-108 | 105 |
| Linearity
Samples were spiked with high concentrations of VB12 and diluted with Universal Diluent to produce samples with values within the range of the assay.| Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
| 1 : 2 | Range (%) | 83-95 | 88-96 | 90-110 |
| Average (%) | 91 | 93 | 96 | |
| 1 : 4 | Range (%) | 89-104 | 87-108 | 105-115 |
| Average (%) | 93 | 98 | 110 |
Size
Quantity
Price ($)
48T
1
360 / 360
96T
1
460 / 460