400-0066-400

Aldosterone (ALD) ELISA Kit

Home  >  Competitive ELISA Kits  >  Aldosterone (ALD) ELISA Kit
Product Name:

Aldosterone (ALD) ELISA Kit

Cat.#:

JL53095

Regulatory Status:
Alternative:

ALD;11β,21-Dihydroxy-3,20-dioxopregn-4-en-18-al;Aldocorten;Aldocortin;Electrocortin;Reichstein X;18;Aldocorticosterone;18-Oxocorticosterone

Detection Method:
ELISA
Assay Type:
Competitive
Detection Range:
31.25-2000pg/mL
Sensitivity:
15.7pg/mL
Specificity:
This kit recognizes ALD in samples. No significant cross-reactivity or interference between ALD and analogues was observed.
Sample Type:
Serum;plasma and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Metabolism
  • Aldosterone (ALD) ELISA Kit
  • Aldosterone (ALD) ELISA Kit
  • Aldosterone (ALD) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| ALD

Aldosterone is the main mineralocorticoid steroid hormone produced by the zona glomerulosa of the adrenal cortex in the adrenal gland.[4][5] It is essential for sodium conservation in the kidney, salivary glands, sweat glands, and colon.[6] It plays a central role in the homeostatic regulation of blood pressure, plasma sodium (Na+), and potassium (K+) levels. It does so primarily by acting on the mineralocorticoid receptors in the distal tubules and collecting ducts of the nephron.It influences the reabsorption of sodium and excretion of potassium (from and into the tubular fluids, respectively) of the kidney, thereby indirectly influencing water retention or loss, blood pressure, and blood volume.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (pg/mL) 2000 1000 500 250 125 62.5 31.25 0
OD 0.15 0.2 0.31 0.52 0.83 1.29 1.63 2.34
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of ALD spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 81-101 96
Plasma(n=8) 92-106 101





 

| Linearity

Samples were spiked with high concentrations of ALD and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4)
1 : 2 Range (%) 83-95 88-96
Average (%) 91 93
1 : 4 Range (%) 89-104 87-108
Average (%) 93 98







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
396 / 396
96T
1
516 / 516