Product Name:
Aflatoxin B1 (Aflatoxin B1) ELISA Kit
Cat.#:
JL49096
Regulatory Status:
Alternative:
Aflatoxin B1
Detection Method:
ELISA
Assay Type:
Competitive
Detection Range:
15.6-1000pg/mL
Sensitivity:
6.8pg/mL
Specificity:
This kit recognizes Aflatoxin B1 in samples. No significant cross-reactivity or interference between Aflatoxin B1 and analogues was observed.
Sample Type:
Serum;plasma;tissue homogenates;cell lysates;cell culture supernates and other biological fluids
Assay Procedure:
Research Area:
Pesticide Residues & Drug Metabolism
Product Datasheets
| Aflatoxin B1
Aflatoxin B1 is an aflatoxin produced by Aspergillus flavus and A. parasiticus. It is a very potent carcinogen.This carcinogenic potency varies across species with some, such as rats and monkeys, seemingly much more susceptible than others.Aflatoxin B1 is a common contaminant in a variety of foods including peanuts, cottonseed meal, corn, and other grains;as well as animal feeds.Aflatoxin B1 is considered the most toxic aflatoxin and it is highly implicated in hepatocellular carcinoma (HCC) in humans.n animals, aflatoxin B1 has also been shown to be mutagenic,teratogenic,and to cause immunosuppression.Aflatoxin B1 is mostly found in contaminated food and humans are exposed to aflatoxin B1 almost entirely through their diet.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (pg/mL) | 1000 | 500 | 250 | 125 | 62.5 | 31.2 | 15.6 | 0 |
| OD | 0.216 | 0.298 | 0.417 | 0.669 | 0.955 | 1.405 | 1.79 | 1.865 |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Aflatoxin B1 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Serum(n=8) | 81-101 | 96 |
| Plasma(n=8) | 92-105 | 101 |
| Cell Culture Supernates(n=8) | 97-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Aflatoxin B1 and diluted with Universal Diluent to produce samples with values within the range of the assay.| Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
| 1 : 2 | Range (%) | 83-95 | 88-96 | 90-110 |
| Average (%) | 91 | 93 | 96 | |
| 1 : 4 | Range (%) | 89-104 | 87-108 | 105-115 |
| Average (%) | 93 | 98 | 110 |
Size
Quantity
Price ($)
48T
1
360 / 360
96T
1
460 / 460