400-0066-400

Cat Glucagon Like Peptide 1 (GLP-1) ELISA Kit

Home  >  Competitive ELISA Kits  >  Cat Glucagon Like Peptide 1 (GLP-1) ELISA Kit
Product Name:

Cat Glucagon Like Peptide 1 (GLP-1) ELISA Kit

Cat.#:

JL54755

Regulatory Status:
Alternative:

Glucagon Like Peptide 1

Detection Method:
ELISA
Assay Type:
Competitive
Detection Range:
78.12-5000pg/mL
Sensitivity:
35.25pg/mL
Specificity:
This kit recognizes Cat GLP-1 in samples. No significant cross-reactivity or interference between Cat GLP-1 and analogues was observed.
Sample Type:
Serum;plasma;tissue homogenates;cell lysates;cell culture supernates and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Cardiovascular Biology
  • Cat Glucagon Like Peptide 1 (GLP-1) ELISA Kit
  • Cat Glucagon Like Peptide 1 (GLP-1) ELISA Kit
  • Cat Glucagon Like Peptide 1 (GLP-1) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| GLP-1

Glucagon-like peptide-1 (GLP-1) is a 30- or 31-amino-acid-long peptide hormone deriving from tissue-specific posttranslational processing of the proglucagon peptide. It is produced and secreted by intestinal enteroendocrine L-cells and certain neurons within the nucleus of the solitary tract in the brainstem upon food consumption. The initial product GLP-1 (1–37) is susceptible to amidation and proteolytic cleavage, which gives rise to the two truncated and equipotent biologically active forms, GLP-1 (7–36) amide and GLP-1 (7–37). Active GLP-1 protein secondary structure includes two α-helices from amino acid position 13–20 and 24–35 separated by a linker region.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (pg/mL) 5000 2500 1250 625 312.5 156.25 78.12 0
OD 0.216 0.298 0.417 0.669 0.955 1.405 1.79 1.865
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Cat GLP-1 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 81-101 96
Plasma(n=8) 92-105 101
Cell Culture Supernates(n=8) 97-108 105





 

| Linearity

Samples were spiked with high concentrations of Cat GLP-1 and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4) Cell Culture Supernates(n=4)
1 : 2 Range (%) 83-95 88-97 90-110
Average (%) 91 93 96
1 : 4 Range (%) 89-104 87-108 105-115
Average (%) 93 98 110







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
396 / 396