400-0066-400

Bovine Estradiol (E2) ELISA Kit

Home  >  Competitive ELISA Kits  >  Bovine Estradiol (E2) ELISA Kit
Product Name:

Bovine Estradiol (E2) ELISA Kit

Cat.#:

JL11602

Regulatory Status:
Alternative:

17B-Estradiol; Oestradiol; Beta-Estradiol

Detection Method:
ELISA
Assay Type:
Competitive
Detection Range:
0.78-50pg/mL
Sensitivity:
0.28pg/mL
Specificity:
This kit recognizes Bovine E2 in samples. No significant cross-reactivity or interference between Bovine E2 and analogues was observed.
Sample Type:
Serum;plasma;tissue homogenates;cell lysates;cell culture supernates and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Signal Transduction
  • Bovine Estradiol (E2) ELISA Kit
  • Bovine Estradiol (E2) ELISA Kit
  • Bovine Estradiol (E2) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| E2

Estradiol (E2), also called oestrogen, oestradiol, is an estrogen steroid hormone and the major female sex hormone.Estradiol is produced within the follicles of the ovaries and in other tissues including the testicles, the adrenal glands, fat, liver, the breasts, and the brain. Estradiol is produced in the body from cholesterol through a series of reactions and intermediates.The major pathway involves the formation of androstenedione, which is then converted by aromatase into estrone and is subsequently converted into estradiol. Alternatively, androstenedione can be converted into testosterone, which can then be converted into estradiol.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (pg/mL) 50 25 12.5 6.25 3.12 1.56 0.78 0
OD 0.216 0.298 0.417 0.669 0.955 1.405 1.79 1.865
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Bovine E2 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 81-102 96
Plasma(n=8) 92-106 101
Cell Culture Supernates(n=8) 97-109 105





 

| Linearity

Samples were spiked with high concentrations of Bovine E2 and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4) Cell Culture Supernates(n=4)
1 : 2 Range (%) 83-95 88-97 90-110
Average (%) 91 93 96
1 : 4 Range (%) 89-105 87-108 105-115
Average (%) 93 98 110







 