400-0066-400

Bovine Estrone (E1) ELISA Kit

Home  >  Competitive ELISA Kits  >  Bovine Estrone (E1) ELISA Kit
Product Name:

Bovine Estrone (E1) ELISA Kit

Cat.#:

JL16483

Regulatory Status:
Alternative:

Oestrone;3-Hydroxyestra-1,3,5(10)-trien-17-one;Oestrone;E1

Detection Method:
ELISA
Assay Type:
Competitive
Detection Range:
31.25-2000pg/mL
Sensitivity:
15.7pg/mL
Specificity:
This kit recognizes Bovine E1 in samples. No significant cross-reactivity or interference between Bovine E1 and analogues was observed.
Sample Type:
Serum;plasma;tissue homogenates;cell lysates;cell culture supernates and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Metabolism
  • Bovine Estrone (E1) ELISA Kit
  • Bovine Estrone (E1) ELISA Kit
  • Bovine Estrone (E1) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| E1

Estrone (E1) is a steroid, a weak estrogen, and a minor female sex hormone.It is one of three major endogenous estrogens, the others being estradiol and estriol.Estrone, as well as the other estrogens, are synthesized from cholesterol and secreted mainly from the gonads, though they can also be formed from adrenal androgens in adipose tissue.Relative to estradiol, both estrone and estriol have far weaker activity as estrogens.Estrone can be converted into estradiol, and serves mainly as a precursor or metabolic intermediate of estradiol.It is both a precursor and metabolite of estradiol.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (pg/mL) 2000 1000 500 250 125 62.5 31.25 0
OD 0.188 0.27 0.389 0.642 0.929 1.38 1.766 1.842
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Bovine E1 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 81-101 96
Plasma(n=8) 92-105 101
Cell Culture Supernates(n=8) 97-108 105





 

| Linearity

Samples were spiked with high concentrations of Bovine E1 and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4) Cell Culture Supernates(n=4)
1 : 2 Range (%) 83-95 88-96 90-110
Average (%) 91 93 96
1 : 4 Range (%) 89-104 87-108 105-115
Average (%) 93 98 110







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
396 / 396
96T
1
576 / 576
Top